Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Sitemtc-m21c.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador8JMKD3MGP3W34R/3SHDA4B
Repositóriosid.inpe.br/mtc-m21c/2019/01.11.16.18
Repositório de Metadadossid.inpe.br/mtc-m21c/2019/01.11.16.18.24
Última Atualização dos Metadados2019:01.12.15.55.18 (UTC) administrator
DOI10.1590/81517-707620180002.0398
ISSN1517-7076
Chave de CitaçãoBahlerPecBruCabTra:2018:StPrSu
TítuloSteel protection for surgical instruments with carbon-based hard coatings type DLC
Ano2018
Data de Acesso06 maio 2024
Tipo de Trabalhojournal article
Tipo SecundárioPRE PN
2. Contextualização
Autor1 Bahler, Eugenia Laura Dalibon
2 Pecina, Jorge Nahuel
3 Bruhl, Sonia Patrícia
4 Cabo, Amado
5 Trava-Airoldi, Vladimir Jesus
Grupo1
2
3
4
5 LABAS-COCTE-INPE-MCTIC-GOV-BR
Afiliação1
2
3
4
5 Instituto Nacional de Pesquisas Espaciais (INPE)
Endereço de e-Mail do Autor1
2
3
4
5 vladimir.airoldi@inpe.br
RevistaMatéria
Volume23
Número2
Páginase12062
Histórico (UTC)2019-01-11 16:18:39 :: simone -> administrator :: 2018
2019-01-12 15:55:18 :: administrator -> simone :: 2018
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Palavras-ChaveDLC coatings
AISI 420
wear
corrosion
surgical instruments
ResumoMartensitic stainless steels can be used in different applications such as surgical instruments where a good wear and corrosion resistance are required. Surface modification treatments such as nitriding improve the mechanical properties of these steels, however; they affect the corrosion resistance. For this reason, the DLC (Diamond Like Carbon) coatings deposition can be convenient. The wear and corrosion behaviour was studied in duplex samples (nitrided and PACVD coated) and they were compared with nitrided and only coated samples and with those without treatment, only heat treated (quench and tempering). The coatings were analyzed by Raman spectroscopy and EDS. Pin on disk tests were performed and the adhesion was evaluated using Scratch Test and Rockwell C Indentation. The nano hardness was measured with a Berkovich indenter. The corrosion tests for surgical instruments (according to the Standard ASTM F 1089-02) and Spray Salt Fog tests were carried out. In the DLC coatings, the I-D/IG ratio was 0.8 and the hydrogen content was calculated and resulted to be about 20 %. The coating thickness was 2 mu m and the hardness reached 24 GPa. The nitrided layer thickness was 10 mu m. The duplex and coated samples presented low friction coefficient and the wear volume loss was undetectable. The coatings had good corrosion behaviour in the corrosion tests. Nevertheless, the nitrided sample presented a corroded region in the copper sulfate and boil tests. The duplex samples had better adhesion than the coated samples in scratch test and indentation Rockwell C.
ÁreaFISMAT
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAS > Steel protection for...
Conteúdo da Pasta docnão têm arquivos
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreement
agreement.html 11/01/2019 14:18 1.0 KiB 
4. Condições de acesso e uso
Idiomaen
Grupo de Usuáriossimone
Grupo de Leitoresadministrator
simone
Visibilidadeshown
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Repositório Espelhourlib.net/www/2017/11.22.19.04.03
Unidades Imediatamente Superiores8JMKD3MGPCW/3ESR3H2
DivulgaçãoWEBSCI; PORTALCAPES.
Acervo Hospedeirourlib.net/www/2017/11.22.19.04
6. Notas
Campos Vaziosalternatejournal archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel e-mailaddress format isbn label lineage mark month nextedition notes numberoffiles orcid parameterlist parentrepositories previousedition previouslowerunit progress project resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark session shorttitle size sponsor subject targetfile tertiarymark tertiarytype url versiontype
7. Controle da descrição
e-Mail (login)simone
atualizar 


Fechar